Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Pesqui. bras. odontopediatria clín. integr ; 21(supl.1): e210028, 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1351224

ABSTRACT

ABSTRACT Objective To evaluate the accuracy of three different digital bracket positioning systems, comparing vertical, mesiodistal and buccolingual accuracy. Material and Methods The same case was sent to Orapix, Insignia, and Orthocad systems and the brackets were bonded to the malocclusion models.Damon 3 MX brackets were used with all systems and the brackets were bonded to the models with the same bonding protocol and materials. The comparison of the position of each single bracket was made with digital photography, and ImageJ software was used to find the length in pixels and then convert it to hundredths of a mm for vertical, mesiodistal and buccolingual displacement, compared to the setup. Results Insignia System reported the average higher vertical displacement (0.28 mm), compared with the other two appliances (0.22-0.23 mm), and showed the lowest average displacement for the mesiodistal and buccolingual positioning (0.14 and 0.07 mm, respectively).However, these slight bracket positioning variations between these bonding systems were not statistically different (p>0.05). Conclusion The three systems analyzed were shown to be accurate in positioning the brackets, and none of them was statistically better.


Subject(s)
Humans , Adult , Orthodontics, Corrective/instrumentation , Orthodontic Brackets , Computer-Aided Design/instrumentation , Data Accuracy , Malocclusion , Analysis of Variance , Statistics, Nonparametric , Photography, Dental/instrumentation , Italy
2.
The Korean Journal of Orthodontics ; : 107-112, 2018.
Article in English | WPRIM | ID: wpr-713383

ABSTRACT

OBJECTIVE: The aim of this study was to examine the properties of fiber-reinforced composite and stainless steel twisted retainers for orthodontic retention. METHODS: Three different span lengths (5.0, 8.0, and 14.0 mm) of fiber-reinforced composite were investigated. The three fiber-reinforced composite retainer groups were subdivided according to the storage condition (dry and wet), resulting in a total of six groups. Each stainless steel and fiber-reinforced composite group was comprised of six specimens. The three-point bending flexural test was conducted using a universal testing machine. ANOVA was used to assess differences in the maximum load and maximum stress according to the span length, material, and storage condition. Post-hoc comparisons were performed if necessary. RESULTS: The maximum stress and maximum load were significantly (p < 0.001) associated with the span length, material, and storage condition. The significant interaction between the material and span length (p < 0.001) indicated the differential effects of the material for each span length on the maximum stress and maximum load, with the difference between materials being the highest for the maximum span length. CONCLUSIONS: Our findings suggest that fiber-reinforced composite retainers may be an effective alternative for orthodontic retention in patients with esthetic concerns or allergy to conventional stainless steel wires.


Subject(s)
Humans , Hypersensitivity , Orthodontic Retainers , Polymers , Stainless Steel
SELECTION OF CITATIONS
SEARCH DETAIL